  • How to protect an inductor (coil) of a Pressure/current converter by inserting a device in series with the loop 4-20ma? December 10, 2019
    hello guys i have pressure/current converter SRI983 where its main electronic component is the coil that changes current to pressure or the opposite .and this transmitter is 24V and 4-20ma . but i'm facing a big issue of damaged coils for a years and now someone suggested a solution to install a fuse in the […]
  • What happened to the daily email of new posting? December 10, 2019
    I have been away for several weeks but am no longer receiving the daily email of new discussions. How do I get signed back up for this?
  • Configuring FactoryTalkView SE December 10, 2019
    I have an Engineering WorkStation EWS Running FactoryTalkView SE , Two Servers (Dell R730 Redundant servers Running the Data Server HMI/Graphics Applications), One FactoryTalk Client (Operator Workstation). Please Do any one have sequence of steps of configuring/ setting up the server to run in Redundant mode (The servers OS is Windows Server 2008 R2 Standard […]
  • Fire fighting system leaking. December 10, 2019
    Our plant has underground fire fighting water line which is developing leaks frequently. Line is GRP line. Did anyone faced this issue? What’s the remedy for this issue?proposals were there to make the line above ground but it’s costly procedure. Thanks and regards.
  • Citect SQL Problem December 10, 2019
    hello everyone, i'm new at citect scada and i use vijeo citect 2015. and i use mssql 2017. i wrote a cicode to store same values in sql database.But i can't insert real type values. i designed my sql table with real type but i cant insert. i only insert if i design it with […]
  • What could be the causes of P/I transmitter damaging coil? December 10, 2019
    a P/I transmitter is used to control a gas valve position , but i'm facing a problem of damaging these transmitter they are based on a coil....if it is from the PLC Allen Bradley (4-20 ma) suggest me the best protection for my loop to keep the coil from harm .
  • Water Control Unit Application December 9, 2019
    Hello, We are working on a custom water temperature unit that will consist of a motor, temperature probe, and valve automatically adjust to temperature changes. My question is what kind of processor should I look at for the monitoring. We'd also like to have a simple display along with it. I have experience with PLCs, […]
  • RPM drop in Engine December 9, 2019
    Hello , We have a diesel CAT gen set.. The gen-set is operated in parallel to another 4 units of same ratings . The gen-set drops RPM suddenly to Zero in fraction of a second and comes back to its rated RPM 1200. Hence there is an condition of reverse power for a short duration. […]
  • Mark VIe tracing out the trip trigger December 7, 2019
    I am fairly new to the gas turbine control system. so pre-apology for any stupidity that may come out. I want to know how the trip trigger can be traced out from trip log that is saved after trip. All of the personnel at site are fairly new to the Mark VIE systems so usually […]
  • Simatic OPC Scout 2.3 December 7, 2019
    Hello, I need the manual/datasheet for Simatic OPC Scout 2.3. I have a testing machine of pneumatic valves. It is controlled by Simatic S7-300 and communicate with LabVIEW 7.1 using OPC Scout 2.3. It is running on old Siemens PC with Windows 2000 (it has integrated Profibus for connect to PLC). I need to create […]